(INST-C002) PVC-Individual Pair + Overall Almylar Screen-PVC

Technical Details

Design Standard As per JSS 51038, JSS 51037, JSS 51034, IS 8130
Conductor Annealed Bare Copper/Nickel Plated Copper/Silver Plated Copper
Conductor Type Solid wire (Class 1) /Stranded (Class 2)/ Flexible (Class 5)
No of Pair 1,2,3,4,6,8 or as per customer requirements
Conductor Size(Sqmm) 0.50/0.75/1.0/1.5 sqmm or as per customer specifications
Insulation Extruded FEP
Core Identification As per BS 5308 & as per customer requirements
Screening Individual & Overall pair Almylar tape screening along with ATC Drain wire with 100 % Coverage area
Outer Sheath Extruded FEP
Outer Colour Blue / Black or as per Customer Requirement
Voltage Grade 300V / 500V / 1100V
Cable Temperature Range -65 Deg C to Up to 205 Deg C

Electrical Characteristics

 

Parameter

Unit

Conductor Size

Size

Sqmm

0.5

0.75

1.0

1.5

Max. Resistance at 20 Deg c

Ohm/Km

36.8

25.0

18.4

12.3

Max. Mutual Capacitance between cores

Pf/m

115

115

115

120

Max. Capacitance between core to screen

Pf/m

400

400

400

400

Insulation Resistance at 20 °C

Mohm-Km

> 1500

Tested Voltage

KVac

1.0 Kv for 1 Minute

Min Bending Radius

Mm

10 X OD

Categories: ,

Applications:

  • For Signal & Data Transmission used in measurement & control technology in high temperature zone
  • Analogue & Digital signal transmission
  • Industry plant, power station, refineries, petrochemical plants etc.
  • Process control, computers, control systems & monitor networks etc.

Features:

  • Flame & Fire Resistance
  • Halogen Free & Low smoke
  • Enhance thermal, electrical & fire properties
  • Good Flexibility
  • Excellent Dielectric Strength
  • Excellent Insulation resistance
  • Suitable for analogue signal transmission
  • Excellent Heat resistance & chemical resistance characteristics
  • Oil & Water Resistance