(CONTROL-C004) PVC Insulation-Braided Screen-PVC Sheathed
September 8, 2018HEATCHEM-600W (Water resist) Polyimide-Mica-Double PTFE –-Double Fiber Glass-Inner PTFE-Mica- Fiber Glass-Asbestos-SS Briding
September 10, 2018
(CHEMOSENS 800) Fiber Glass & Asbestos Lapping
Technical Details
Design Standard
|
ANSI MC 96.1 , IEC 60584.3 & ASTM E230/77
|
Conductor
|
K type original conductor & N type original conductor
|
Conductor Type
|
Solid wire (Multistrand optional)
|
No of Pair
|
Single Pair
|
Conductor Size
|
AWG 24 AWG to 14 AWG or Variant as per customer specifications
|
Insulation
|
Fiber Glass & Asbestos yarn lapping with PTFE Impregnated varnish
|
Cable formation
|
Both cores twisted together (Without Jacket)
|
Outer Colour
|
As per ANSI MC 96.1 or as per customer specifications
|
Accuracy
|
As per ANSI MC 96.1 / IEC 60584.3
|
Temperature Range
|
Up to 800 Deg C
|
Applications:
- Metal Production
- Heat treatment
- Temperature sensor
- Brick & Tile kiln
- Industry plant, power station, refineries, petrochemical plants etc.
- In Laboratory for calibration of high temperature furnaces
- In Defence, Glass, Steel & Sponge, Cement, Nuclear & many more sectors.
Features:
- Continues use up to 800 Deg C
- Single exposure up to 1000 Deg C
- Excellent Chemical resistance
- Excellent Heat resistance
- Halogen free
- Better Flexibility
- Flame retardant
- Good corrosion resistance
- Good thermal durability
- Excellent Heat resistance
Note:
- This wires are not water resistance, oil resistance & moisture resistance
- For use in dry condition
- Lower dielectric strength
- Used for fixed installation only
- Multiple use of this wire reduces its life & lower the strength